Pilz PSENvip R Operating Manual page 36

Safe camera systems
Table of Contents

Advertisement

Function description
Side intervention with full protected field or reduced protected field during the dynamic mut-
ing
Object interrupts the protected
field to the side:
OSSD signal: 1->0
Mute signal: 1
LED OSSD = goes out
LED Mute = lights
Control system initiates the stop-
ping of the press stroke.
Upper tool continues moving for
the overrun distance, protected
field interrupted. Object is re-
moved. Protected field cleared.
Press stroke can be resumed.
Operating Manual PSENvip R, PSENvip R LR,PSENvip E
1003449-EN-06
| 36

Advertisement

Table of Contents
loading

This manual is also suitable for:

Psenvip r lrPsenvip e

Table of Contents