Pilz PSENvip R Operating Manual page 9

Safe camera systems
Table of Contents

Advertisement

Overview
PSENvip is part of an overall system comprising:
Press brake
}
Numerical controller (CNC) with web interface for visualisation and operation
}
PSENvip transmitter and PSENvip receiver
}
Control system PSSuniversal PLC from the automation system PSS 4000 with special
}
module PSSu K F FAU
PAS4000 user program
}
Transmitter
Fig.: Whole system
If the detection zone between transmitter and receiver is interrupted, the PSSu K F FAU
can shut down the safety outputs immediately. The outputs that are shut down are defined
in the PAS4000 user program.
There are 2 versions available for protected field monitoring:
The base version monitors a fixed, configured protected field.
}
The productive version monitors a dynamic protected field.
}
PSENvip automatically detects a tool contour. The adjustment during initial commissioning
or during a tool change is made using the web interface on the CNC.
Operating Manual PSENvip R, PSENvip R LR,PSENvip E
1003449-EN-06
Monitor
Web Interface
Control system
PSSuniversal
PSSu K F FAU
Control cabinet
Receiver
Press brake
Upper die
Upper tool
Detection zone
Lower tool
PSSu K F FAU
Transmitter
| 9