Commissioning
Sequence
Function test using the test rod (= test piece handle)
Move the test rod (14 mm diameter) slowly along the whole detection zone at the tip of
}
the upper tool.
Fig.: Function test using test rod
The test rod must be detected along the whole length of the detection zone.
The OSSD signal switches from 1 to 0. The LED on the receiver lights up red.
Function test with 10 mm and 15 mm test piece
Position the 10 mm high section of the test piece on top of the lower tool.
}
Initiate a press stroke.
}
Fig.: Function test using test piece
Operating Manual PSENvip R, PSENvip R LR,PSENvip E
1003449-EN-06
INFORMATION
The following tests should be carried out 10 times during initial commission-
ing.