Commissioning
The test piece breaks the protected field. The press stroke is stopped. The upper tool
should not touch the test piece.
Once the press stroke has stopped, push the 15 mm high section of the test piece be-
}
neath the upper tool.
The upper tool should not touch the test piece.
Function test using the 35 mm test piece
Move the press to top dead centre.
}
Position the 35 mm high section of the test piece on top of the lower tool.
}
Initiate a press stroke.
}
The test piece breaks the protected field. The press stroke is stopped. The upper tool
should not touch the test piece.
Operating Manual PSENvip R, PSENvip R LR,PSENvip E
1003449-EN-06
WARNING!
The press brake must be shut down immediately if the test reveals a
fault!
Failure to comply could result in a hazardous situation, which could lead
to serious injury and death.
In this case, have the safety equipment checked by qualified staff.