Tool Change And Adjustment After Tool Change - Pilz PSENvip R Operating Manual

Safe camera systems
Table of Contents

Advertisement

Operation
8.2

Tool change and adjustment after tool change

When a tool is changed, the tool must be repositioned and then an adjustment must be car-
ried out. Both processes are carried out in the web interface. The process is described un-
der "Commissioning":
Position tool [
}
Make adjustment during tool change [
}
In the web interface, when a tool change is requested via the Tool Change menu or an ad-
justment is requested after a tool change via the Adjustment menu, protected field monit-
oring is interrupted and:
The LED on the receiver lights up red.
}
The web interface shows the selected menu. The symbol for the OSSD is red.
}
PSSu K F FAU: The SUP LED goes out. The meaning of the remaining LEDs is de-
}
scribed in the operating manual PSSu K F FAU B, PSSu K F FAU P.
Once the adjustment (Adjustment) or tool change (Tool Change) is complete, the system
runs a test. Once the test has been completed successfully, the system starts protected
field monitoring automatically. If an error is detected during the test, protected field monitor-
ing will not be started and an error is reported.
Operating Manual PSENvip R, PSENvip R LR,PSENvip E
1003449-EN-06
88]
92]
| 104

Advertisement

Table of Contents
loading

This manual is also suitable for:

Psenvip r lrPsenvip e

Table of Contents