Major Errors - Pilz PSENvip R Operating Manual

Safe camera systems
Table of Contents

Advertisement

Diagnostics and Troubleshooting
9.1.2

Major errors

Major errors can include:
Internal errors
}
Interface errors, e.g. between PSSu K F FAU and transmitter/receiver
}
Wiring errors or electromagnetic interference
}
Reaction:
After a major error, the outputs on the PSSu K F FAU are shut down and the Err LED lights
up red. The transmitter is off and the receiver on the LED lights up red. PSENvip is restar-
ted automatically. The restart is carried out up to 3 times. If the error is still present after-
wards, PSENvip remains switched off. The error is displayed via the web interface (if pos-
sible) and is reported to the PSSu system.
Remedy: Rectify the error and then restart the PSENvip (switch supply voltage off and then
on again). If this doesn't help, exchange the device.