System Cycle For Overrun Measurement - Pilz PSENvip R Operating Manual

Safe camera systems
Table of Contents

Advertisement

Function description
4.8.5

System cycle for overrun measurement

The overrun is measured using the central segments of the protected field. The status of
evaluation field A is evaluated during overrun measurement. The evaluation field is 6 mm
below the tool centre point. The overrun measurement begins when the protected field is in-
terrupted.
A: Evaluation field
P: Test piece
v
: maximum closing speed
max
x: Set overrun
y: Measured overrun
OverrunMeasurement: Signal for overrun from the special module PSSu K F FAU (see op-
erating manual of the PSSu K F FAU B, PSSu K F FAU P)
Downward movement with maximum closing speed v
}
Protected field: Free
Signal/action
OverrunMeasurement
Overrun measurement
Downward movement with maximum closing speed v
}
start of overrun measurement
Protected field: Interrupted
Signal/action
OverrunMeasurement
Overrun measurement
Operating Manual PSENvip R, PSENvip R LR,PSENvip E
1003449-EN-06
Status
Press
0
0
Status
Press
1
1 (evaluation field
clear)
max
A
v max
x
P
, braking process initiated,
max
A
v max
x
P
| 49