Pilz PSENvip R Operating Manual page 16

Safe camera systems
Table of Contents

Advertisement

Safety
Tool class 3
These tools cannot be safeguarded in compliance with the standards: The front and rear
}
bending lines are not detected by the protected field on the PSENvip.
Under the following conditions, this tool class must be evaluated in the PAS4000 user
}
program:
– after the PSENvip is switched on
– after a tool change
– after the control system is restarted
Please refer to the information in the operating manual for the PSSu K F FAU P (see un-
der "Communication with the safety system").
The following safety guideline applies for press brakes with tools in this tool class.
}
Please also note the following guidelines in danger zones in areas that cannot be detected
and monitored by the safeguard.
Operating Manual PSENvip R, PSENvip R LR,PSENvip E
1003449-EN-06
WARNING!
Hazard areas that are not monitored by the PSENvip!
Additional hazard areas in zones that are not monitored by the PSENvip
can lead to serious injuries (fingers or hands being crushed or trapped).
Secure these zones with appropriate additional measures:
– Carry out a hazard analysis.
– Raise the regular switchover point, which initiates braking at low
speed. The switchover point must be monitored by the safety system.
– Each press stroke must be acknowledged by the operator prior to ini-
tiation.
| 16