4
4.2.4
Mounting on Multi-Pos holder
Use the provided M4 x 8 ISO 14581 countersunk head screws (black) to fasten
the holder to the VESA 100 threaded holes on the rear panel
Mount the holder with the supplied M8 screw, the washers, the handle and the
M8 hexagon nut to an arm
Adjust the desired angle of inclination within the tilting range of 90°
To fix the holder in place: Tighten the T25 screw
Route the cable from behind through the two supports of the holder and then
through the lateral openings to the connections
Figure 8: Product mounted on Multi-Pos
holder
Further information:
44
Comply with the permissible tightening torque of 2.6 Nm
Comply with the tightening torque for screw T25
Recommended tightening torque: 5.0 Nm
Maximum permissible tightening torque: 15.0 Nm
"Product dimensions with Multi-Pos holder", Page 307
Mounting | Assembly of the product
Figure 9: Cable routing on Multi-Pos
holder
HEIDENHAIN | POSITIP 8000 | Operating Instructions Milling | 03/2020