Settings | Axes
Parameters
Outputs
Inputs
Software limit switches
Start-up time
Kv factor P
Kv factor L
Maximum positioning error
Maximum standstill error
Positioning window
Minimum dwell time in manual
positioning window
HEIDENHAIN | POSITIP 8000 | Operating Instructions Milling | 03/2020
Explanation
Configuration of the Outputs for the NC function
Further information:
"Outputs", Page 258
Configuration of the Inputs for the NC function
"Inputs", Page 260
Further information:
Configuration of the Software limit switches
Further information:
"Software limit switches", Page 263
Configuration of the acceleration behavior and the braking behav-
ior of the axis; time during which the drive accelerates from
standstill to maximum feed rate Fmax or decelerates from
maximum feed rate to standstill.
Setting range: 50 ms ... 10000 ms
Default value: 500
Proportional component of the position controller during position-
ing
Setting range: 0.3 m/(min x mm) ... 6 m/(min x mm)
Default value: 2.5
Proportional component of the position controller at a standstill
Setting range: 0.3 m/(min x mm) ... 6 m/(min x mm)
Default value: 2.5
Definition of the maximum following error during positioning
Setting range: 5 µm ... 1000 µm
Default value: 500
Definition of the maximum position deviation at a standstill
Setting range: 5 µm ... 1000 µm
Default value: 100
Input of the scaling factor for the positioning aid in MDI mode
(only for manually operated linear axes)
Setting range: 0.020 mm ... 2.000 mm
Default value: 0.100
The entered required amount of time for the axes to be in the
positioning window until the block is completed (only for manual-
ly operated linear axes)
Setting range: 0 ms to 10000 ms
Default value: 0 ms