AT commands
Parameter range
0 - 0xFFFF (bit field)
Default
0
t b

IR (Sample Rate)

WARNING! If you set IR to 1 or 2, the device will not keep up and many samples will be
lost.
Set or read the I/O sample rate to enable periodic sampling.
When set, this parameter causes the device to sample all enabled digital I/O and analog inputs at a
specified interval. Samples will be sent to the address specified by the DH and DL commands. The
target device must be operating in API mode in order to output the received sample data.
To enable periodic sampling, set IR to a non-zero value, and enable the analog or digital I/O
functionality of at least one device pin (D0 – D9, P0 – P9).
Parameter range
0 - 0xFFFF (x 1 ms)
Default
0

TP (Temperature)

Displays the temperature of the XLR PRO RF Module in degrees Celsius. The temperature value is
displayed in 8-bit two's compliment format. For example, 0x1A = 26 °C, and 0xF6 = -10 °C.
Because the XLR PRO RF Module produces heat, this temperature reading is usually above the
ambient temperature.
Parameter range
0 - 0xFF which indicates degrees Celsius displayed in 8-bit two's compliment format.
Default
N/A
%V (Voltage Supply Monitoring)
Displays the supply voltage of the device in mV units.
Parameter range
0 - 0xFFFF [read-only]
Default
N/A
XLR PRO Radio Frequency (RF) Module User Guide
I/O sampling commands