AT Command: ATRT
1
2
Default Parameter Value: 0
Number of bytes returned: 1
Related Commands: SM (Sleep Mode), ST (Time before Sleep)
SB (Stop Bits) Command
<Serial Interfacing> The SB Command is used to set/read the number of stop bits in the data packet.
AT Command: ATSB
Binary Command: 0x37 (55 decimal)
Parameter Range: 0 - 1
Parameter
0
1
Default Parameter Value: 0
Number of bytes returned: 1
SH (Serial Number High) Command
<Diagnostics> SH Command is used to set/read the serial number high word of the RF module.
AT Command: ATSH
Binary Command: 0x25 (37 decimal)
Parameter Range (read-only): 0 - 0xFFFF
Default Parameter Value: varies
Number of bytes returned: 2
Related Commands: SL (Serial Number Low)
XTend RF Module User Guide
Enable Binary Programming
Enable RTS Flow Control
Configuration
1 stop bit
2 stop bits
Command descriptions