Digi XLR PRO User Manual page 85

Radio frequency (rf) module
Hide thumbs Also See for XLR PRO:
Table of Contents

Advertisement

Operate in API mode
Example
The following example illustrates an AT Command frame when you query the device's NH parameter
value.
Frame data fields
Start delimiter
Length
Frame type
Frame ID
AT command
Parameter value (NH2 = two network hops)
Checksum
XLR PRO Radio Frequency (RF) Module User Guide
API frames
Offset
Example
0
0x7E
MSB 1
0x00
LSB 2
0x04
3
0x08
4
0x52
5
0x4E (N)
6
0x48 (H)
7
0x02
8
0x0D
85