AT commands
T1 (D1 Timeout)
Specifies how long pin D1 holds a given value before it reverts to configured value. If set to 0, there is
no timeout.
Parameter range
0 - 0x1770 (x 100 ms)
Default
0
T2 (D2 Timeout)
Specifies how long pin D2 holds a given value before it reverts to configured value. If set to 0, there is
no timeout.
Parameter range
0 - 0x1770 (x 100 ms)
Default
0
T3 (D3 Timeout)
Specifies how long pin D3 holds a given value before it reverts to configured value. If set to 0, there is
no timeout.
Parameter range
0 - 0x1770 (x 100 ms)
Default
0
T4 (D4 Timeout)
Specifies how long pin D4 holds a given value before it reverts to configured value. If set to 0, there is
no timeout.
Parameter range
0 - 0x1770 (x 100 ms)
Default
0
T5 (D5 Timeout)
Specifies how long pin D5 holds a given value before it reverts to configured value. If set to 0, there is
no timeout.
Parameter range
0 - 0x1770 (x 100 ms)
XLR PRO Radio Frequency (RF) Module User Guide
I/O line passing commands
73