AT commands
Parameter range
0 - 0xFFFF
Default
N/A (0 after reset)

TR (Transmission Failure Count)

Reports or resets the total number of unicast transmissions for which all retries failed with no MAC
ACK from the destination node, up to a maximum of 0xFFFF transmission failures. After 0xFFFF,
failures are no longer counted. You can reset the counter to any 16-bit value within the valid range by
appending a hexadecimal value to the TR command.
TR is a volatile value—that is, the value does not persist across device resets.
Parameter range
0 - 0xFFFF
Default
N/A

UA (Unicasts Attempted)

Reports or resets the total number of MAC unicast transmissions for which an ACK is requested, up to
a maximum of 0xFFFF transmissions. After 0xFFFF, additional transmissions are not counted. You can
reset the counter to any 16-bit value within the valid range by appending a hexadecimal value to the
UA command.
UA is a volatile value—that is, the value does not persist across device resets.
Parameter range
0 - 0xFFFF
Default
0

%H (MAC Unicast One Hop Time)

The MAC unicast one hop time timeout in milliseconds. If you change the MAC parameters it can
change this value.
Parameter range
[read-only]
Default
0x267

%8 (MAC Broadcast One Hop Time)

The MAC broadcast one hop time timeout in milliseconds. If you change MAC parameters, it can