2.1.3

Structural

Installation
*1
The front face of the PS-G unit, installed in a solid panel, has been tested using conditions equivalent to
the standards shown in the specification. Even though the PS-G unit's level of resistance is equivalent to
these standards, oils that should have no effect on the PS-G can possibly harm the unit. This can occur in
areas where either vaporized oils are present, or where low viscosity cutting oils are allowed to adhere to
the unit for long periods of time. If the PS-G's front face protection sheet becomes peeled off, these
conditions can lead to the ingress of oil into the PS-G and separate protection measures are suggested.
Also, if non-approved oils are present, it may cause deformation or corrosion of the front panel's plastic
cover. Therefore, prior to installing the PS-G be sure to confirm the type of conditions that will be
present in the PS-G's operating environment.
If the installation gasket is used for a long period of time, or if the unit and its gasket are removed from
the panel, the original level of the protection cannot be guaranteed. To maintain the original protection
level, be sure to replace the installation gasket regularly.
Grounding resistance of 100 Ω, 2mm
Grounding
or your country's applicable standard. (Same for FG and SG
terminals)
*1
Rating
Structure
Installation method: Panel/VESA Arm
Cooling
Natural air circulation
Method
Weight
Approx. 3.5kg [7.7lb] (unit only)
External
W313mm [12.32in.] x H239mm [9.41in.] x D56mm [2.20in.]
Dimensions
: Equivalent to IP65f