PS-3600G Series User Manual
Connecting the Power Cord
When connecting the AC type power cord, be sure to follow the procedures given below.
(1) Be sure that the PS-G's power cord is not plugged in to the power supply.
(2) Remove the Terminal Srtip's clear plastic cover.
(3) Remove the screws from the two (2) terminals (L,N) and FG (Frame Ground) Terminal, position the Ring
Terminals and reattach the screws. (Check each wire to make sure the connections are correct.)
(4) Reattach the Terminal Strip's clear plastic cover.
3-8
• The torque required to tighten these screws are as follows:
Terminal Block: 0.5 to 0.6N
FG (Frame Ground) Terminal: 0.6 to 0.7N
DON'T
CONNECT
•
m
•
m
FG (Frame Ground) Terminal