7.2 Periodic Check Points
To keep your PS-G unit in its best condition, please inspect the following points periodically.
PS-G Operation Environment
•
Is the operating temperature within the allowable range (0°C to 50°C)?
•
Is the operating humidity within the specified range (10%RH to 90%RH, dry bulb temperature of 39°C or
less)?
•
Is the operating atmosphere free of corrosive gasses?
When using the PS-G unit inside a panel, the ambient environment refers to the interior of the panel.
Electrical Specifications
•
Is the input voltage appropriate?
PS3600G-T41: AC100 to 240V 50/60Hz
PS3600G-T41-24V: DC19.2 to 28.8V
Related Items
•
Are all power cords and cables connected properly? Have any become loose?
•
Are all mounting brackets holding the unit securely?
•
Are there many scratches or traces of dirt on the installation gasket?
Chapter 7 Maintenance
7-3