Structural Specifications - Pro-face FP2600-T11 User Manual

Table of Contents

Advertisement

(Continued from previous page)
*1
The front face of the FP unit, installed in a solid panel, has been tested using
conditions equivalent to the standard shown in the specification . Even though
the FP unit's level of resistance is equivalent to the standard, oils that should
have no effect on the FP can possibly harm the unit. This can occur in areas
where either vaporized oils are present, or where low viscosity cutting oils are
allowed to adhere to the unit for long periods of time. If the FP's front face
protection sheet becomes peeled off, these conditions can lead to the ingress of
oil into the FP and separate protection measures are suggested. Also, if non-
approved oils are present, it may cause deformation or corrosion of the front
panel's plastic cover. Therefore, prior to installing the FP be sure to confirm the
type of conditions that will be present in the FP's operating environment.
If the installation gasket is used for a long period of time, or if the unit and its
gasket are removed from the panel, the original level of the protection cannot be
guaranteed. To maintain the original protection level, you need to replace the
installation gasket regularly.

2-1-3 Structural Specifications

2-2
External Dimensions
Weight
Cooling System
AC100V (FP2600-T11)
317W x 243H x 58D mm
3.5 kg or less
Natural air circulation
FP2600-T11 User Manual
Specifications