Western Digital Ultrastar Serv60+8 User Manual page 392

Hide thumbs Also See for Ultrastar Serv60+8:
Table of Contents

Advertisement

User Guide
Note: When installing SSDs for this configuration, the preinstalled HDDs will have to be moved
one entire row to the next vacant row near the front of the enclosure.
Figure 496: Minimum HDD and Minimum SSD Partial Population
Minimum HDD and Maximum SSD Partial Population:
The enclosure supports a minimum of 24 HDDs and one SSD in the drive bay and a configuration of no
SSDs in the center channel for a partially populated enclosure. The enclosure can support a maximum of up
to 24 total SSDs in this configuration. The center SSD channel supports a minimum configuration of no SSDs
with a maximum of eight SSDs. The center channel SSDs must be populated from the drive slots closest to
the rear IO first, starting with drive slot 67 and work backward. The remaining unpopulated center channel
drive slots must be populated with drive blanks until the center channel is full. The enclosure does not
support a mix of SAS and SATA drives. The image below details the required configuration for minimum
HDD and maximum SSD with the minimum SSD center channel configuration.
Note: When installing SSDs for this configuration, the preinstalled HDDs will have to be moved
two entire rows to the next vacant pair of rows near the front of the enclosure.
5. System Management
5.7 Partially Populated Enclosures
383

Advertisement

Table of Contents
loading

Table of Contents