Western Digital Ultrastar Serv60+8 User Manual page 129

Hide thumbs Also See for Ultrastar Serv60+8:
Table of Contents

Advertisement

User Guide
Step 12 : Uninstall the rest of the system fans in the same manner as the first.
Step 13 : Uninstall server cover panel on both sides of the enclosure that contains the failed CPU and Heat
Sink module.
a. Remove the screws that secure the server cover panels to the chassis using a T7 Torx
screwdriver.
Figure 120: Removing System Fans
Note: The same steps to uninstall the server cover panel apply to both sides of
the enclosure with the exception of the number of screws that secure the server
cover panel. From the rear of the enclosure, the left panel contains two screws.
The panel on the right side of the enclosure contains one screw.
Note: When at the rear of the enclosure, the left server cover panel
contains two T7 Torx screws. The left server cover panel contains only
one T7 Torx screw.
4.8 CPU and Heat Sink Module Replacement
4. Part Replacement
120