Western Digital Ultrastar Serv60 Plus 8 H4060-S Installation Manual
Western Digital Ultrastar Serv60 Plus 8 H4060-S Installation Manual

Western Digital Ultrastar Serv60 Plus 8 H4060-S Installation Manual

Advertisement

Quick Links

Installation
Guide
Ultrastar Serv60+8
Regulatory Model H4060-S
Document D018-000252-000
Revision 01
September 2021

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Ultrastar Serv60 Plus 8 H4060-S and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Western Digital Ultrastar Serv60 Plus 8 H4060-S

  • Page 1 Installation Guide Ultrastar Serv60+8 Regulatory Model H4060-S Document D018-000252-000 Revision 01 September 2021...
  • Page 2: Table Of Contents

    Installation Guide Table of Contents Table of Contents Revision History.............................iii Notices..............................v Points of Contact..........................vi Product Label Information......................vi Chapter 1. Overview......................1 Ultrastar Serv60+8 Description......................2 Ultrastar Serv60+8 Layout........................3 Environmental Specifications......................5 Electrical Specifications........................5 Mechanical Specifications........................6 Performance Specifications......................... 6 Ultrastar Serv60+8 Rack Requirements....................
  • Page 3 Installation Guide Table of Contents Safety and Service..........................36 Chapter 4. Packaging....................37 Ultrastar Serv60+8 Packaging Overview..................38 Ultrastar Serv60+8 Unpacking Procedure..................41 Chapter 5. Installation....................44 Installation Overview..........................45 Rails Installation..........................46 Chassis Installation..........................57 CMA Installation..........................60 Cable Installation..........................62 Cabling for CMA Standard and CMA Lite.................65 Top Cover Installation and Extension Test..................66 Drive Installation..........................
  • Page 4: Revision History

    Installation Guide Revision History Revision History Date Revision Comment June 2018 Initial release August 2018 Updated the following sections: • List of Customer Replaceable Units (CRUs) (topic removed) December 2018 Updated the following section: • List of Compatible Drives (page 10) March 2019 Updated the following sections: •...
  • Page 5 Installation Guide Revision History Date Revision Comment • Separated installation procedure into individual tasks by component Installation (page 44) September 2021 Changed document number from 1ET1114 to D018-000252-000...
  • Page 6: Notices

    Per Western Digital Terms and Conditions of Sale, the user of Western Digital products in life support applications assumes all risk of such use and indemnifies Western Digital against all damages.
  • Page 7: Points Of Contact

    Website: https:/ /portal.wdc.com/Support/s/ UK Import Representation Contact Western Digital UK Limited Hamilton House, Regent Park, Kingston Road Leatherhead, Surrey KT22 7PL, GB, United Kingdom Telephone: +44 1372 366000 1.1   Product Label Information The following product information is required for technical support requests: •...
  • Page 8: Chapter 1. Overview

    Western Digital Overview This section provides a high level overview of the features of the Ultrastar Serv60+8 . In This Chapter: - Ultrastar Serv60+8 Description.....2 - Ultrastar Serv60+8 Layout......3 - Environmental Specifications......5 - Electrical Specifications........ 5 - Mechanical Specifications......6 - Performance Specifications......6...
  • Page 9: Ultrastar Serv60+8 Description

    1. Overview Installation Guide 1.1 Ultrastar Serv60+8 Description 1.1   Ultrastar Serv60+8 Description Figure 2: Ultrastar Serv60+8 The Ultrastar Serv60+8 is a 4U form factor, high density, rack-mounted storage enclosure that is capable of hosting up to 60 HDD SAS or SATA drives. The maximum data storage capacity of the Ultrastar Serv60+8 is 901TB using 14TB Ultrastar®...
  • Page 10: Ultrastar Serv60+8 Layout

    1. Overview Installation Guide 1.2 Ultrastar Serv60+8 Layout • ASPEED AST2500 BMC • Lewisburg PCH C624 Chipset 1.2   Ultrastar Serv60+8 Layout Figure 3: Front and Rear Product Layout Table 1: Front and Rear Component Identification Number Component Enclosure Handles PSUs (Delta PSUs shown) Rear IO Ports Chassis Cover...
  • Page 11 1. Overview Installation Guide 1.2 Ultrastar Serv60+8 Layout Figure 4: Component Layout...
  • Page 12: Environmental Specifications

    1. Overview Installation Guide 1.3 Environmental Specifications Figure 5: Rear IO Ports 1.3   Environmental Specifications Table 2: Environmental Specification Summary Specification Non-Operational Operational Temperature -40°C to 70°C 5°C to 35°C Temperature Gradient 30°C per hour maximum 20°C per hour maximum Temperature De-rating 1°C per 300m above 3000m 1°C per 300m above 900m...
  • Page 13: Mechanical Specifications

    1. Overview Installation Guide 1.5 Mechanical Specifications Specification Value Typical Power Consumption ~1800W Input Voltage 200 - 240 VAC PSU Connector Type PSU Efficiency 80 PLUS Platinum Inrush Current Maximum (per AC line inrush current shall not exceed 35A peak PSU) measured per IPC-9592B(L) Appendix C-4.1.
  • Page 14: Ultrastar Serv60+8 Rack Requirements

    1. Overview Installation Guide 1.7 Ultrastar Serv60+8 Rack Requirements Table 5: Performance Specifications Specification Value Mother Board Intel Sawtooth Pass S2600ST Processor Type Intel Skylake or Cascade Lake Socket LGA3647-0 (Socket P) processor sockets Number of Processors Chipset Lewisburg PCH C624 Chipset Memory Type DDR4 ECC DIMM Number of Memory Slots...
  • Page 15: Compatible Rack Hardware Configuration

    1. Overview Installation Guide 1.7 Ultrastar Serv60+8 Rack Requirements The following section provides specific information necessary to install, service, and remove the Ultrastar Serv60+8 . The installation of the Ultrastar Serv60+8 requires two people and a space of 1524mm / 60in. in front of the installation space.
  • Page 16 1. Overview Installation Guide 1.7 Ultrastar Serv60+8 Rack Requirements PDU Mounting Additional Mounting Parameter Rack PDU (Vertical) Bracket Bracket Hardware 4 x M6 Hex Nut with Nylon Lock Quantity Varies Table 8: Compatible Hardware Configuration 2 PDU Mounting Additional Mounting Parameter Rack PDU (Vertical)
  • Page 17: List Of Compatible Drives

    Washers 4 x M6 Hex Nut with Nylon Lock Quantity 1 rack Varies 1.8   List of Compatible Drives HDD with 3.5-inch Drive Carrier Table 11: Western Digital Ultrastar DC HC310 Sector Drive Type Interface Encryption Volume Part Number Size...
  • Page 18 1. Overview Installation Guide 1.8 List of Compatible Drives Table 12: Western Digital Ultrastar DC HC320 Sector Drive Type Interface Encryption Volume Part Number Size Ultrastar DC HC320 SATA 6Gb/s 512e 1EX1227 w/ 3.5 in. drive carrier Ultrastar DC HC320...
  • Page 19 10TB 1EX0483 w/ 3.5 in. drive carrier Ultrastar DC HC510 SAS 12Gb/s TCG-FIPS 10TB 1EX1340 w/ 3.5 in. drive carrier Table 14: Western Digital Ultrastar DC HC520 Sector Drive Type Interface Encryption Volume Part Number Size Ultrastar DC HC520 SATA 6Gb/s...
  • Page 20 12TB 1EX1005 w/ 3.5 in. drive carrier Ultrastar DC HC520 SAS 12Gb/s TCG-FIPS 12TB 1EX1339 w/ 3.5 in. drive carrier Table 15: Western Digital Ultrastar DC HC530 Sector Drive Type Interface Encryption Volume Part Number Size Ultrastar DC HC530 SATA 6Gb/s...
  • Page 21 18TB 1EX2480 w/ 3.5 in. drive carrier Caution: Ultrastar DC HC650 drives are only compatible with the OSs and HBAs listed in the following table. Table 17: Western Digital Ultrastar DC HC650 Kernel HBA FW HBA Driver 9400-8e Ubuntu 18.04 4.15.0-76-generic...
  • Page 22 1. Overview Installation Guide 1.8 List of Compatible Drives Table 18: Western Digital Ultrastar SS200 Part Drive Type Interface Drive Writes Encryption Volume Number Ultrastar SS200 No longer SAS 12Gb/s RI-3DW/D 400GB w/ 2.5 in. drive carrier available Ultrastar SS200...
  • Page 23 2.5 in. drive carrier available Ultrastar SS300 No longer SAS 12Gb/s ME-10DW/D TCG-FIPS 1.6TB w/ 2.5 in. drive carrier available Table 20: Western Digital Ultrastar SS530 Part Drive Type Interface Drive Writes Encryption Volume Number Ultrastar SS530 SAS 12Gb/s...
  • Page 24 1. Overview Installation Guide 1.8 List of Compatible Drives Part Drive Type Interface Drive Writes Encryption Volume Number w/ 2.5 in. drive carrier Ultrastar SS530 SAS 12Gb/s ME-10DW/D 400GB 1EX2074 w/ 2.5 in. drive carrier Ultrastar SS530 SAS 12Gb/s RI-1DW/D 480GB 1EX2006 w/ 2.5 in.
  • Page 25 1. Overview Installation Guide 1.8 List of Compatible Drives Part Drive Type Interface Drive Writes Encryption Volume Number Ultrastar SS530 SAS 12Gb/s RI-1DW/D 1.92TB 1EX2011 w/ 2.5 in. drive carrier Ultrastar SS530 SAS 12Gb/s RI-1DW/D 1.92TB 1EX2082 w/ 2.5 in. drive carrier Ultrastar SS530 SAS 12Gb/s RI-3DW/D...
  • Page 26 1. Overview Installation Guide 1.8 List of Compatible Drives Table 21: Western Digital Ultrastar SS540 Part Drive Type Interface Drive Writes Encryption Volume Number Ultrastar SS540 SAS 12Gb/s RI-3DW/D 800GB 1EX2550 w/ 2.5 in. drive carrier Ultrastar SS540 SAS 12Gb/s...
  • Page 27 15.36TB 1EX2556 w/ 2.5 in. drive carrier Ultrastar SS540 SAS 12Gb/s RI-1DW/D TCG-FIPS 15.36TB 1EX2557 w/ 2.5 in. drive carrier Table 22: Western Digital Ultrastar SA620 Part Drive Type Interface Drive Writes Encryption Volume Number Ultrastar SA620 No longer SATA 6Gb/s RI-0.6DW/D...
  • Page 28 Ultrastar SA620 No longer SATA 6Gb/s RI-0.6DW/D 1.92TB w/ 2.5 in. drive carrier available SSD with 3.5-inch to 2.5-inch Drive Carrier Table 23: Western Digital Ultrastar SS200 Part Drive Type Interface Drive Writes Encryption Volume Number Ultrastar SS200 No longer...
  • Page 29 3.5 in. to 2.5 in. drive carrier available Ultrastar SS200 No longer SAS 12Gb/s RI-1DW/D 7.68TB w/ 3.5 in. to 2.5 in. drive carrier available Table 24: Western Digital Ultrastar SS300 Part Drive Type Interface Drive Writes Encryption Volume Number Ultrastar SS300 No longer...
  • Page 30 3.5 in. to 2.5 in. drive carrier available Ultrastar SS300 No longer SAS 12Gb/s RI-3DW/D 3.2TB w/ 3.5 in. to 2.5 in. drive carrier available Table 25: Western Digital Ultrastar SS530 Part Drive Type Interface Drive Writes Encryption Volume Number Ultrastar SS530 SAS 12Gb/s...
  • Page 31 1. Overview Installation Guide 1.8 List of Compatible Drives Part Drive Type Interface Drive Writes Encryption Volume Number w/ 3.5 in. to 2.5 in. drive carrier Ultrastar SS530 SAS 12Gb/s ME-10DW/D 400GB 1EX2012 w/ 3.5 in. to 2.5 in. drive carrier Ultrastar SS530 SAS 12Gb/s ME-10DW/D 400GB...
  • Page 32 1. Overview Installation Guide 1.8 List of Compatible Drives Part Drive Type Interface Drive Writes Encryption Volume Number Ultrastar SS530 SAS 12Gb/s ME-10DW/D 1.6TB 1EX2085 w/ 3.5 in. to 2.5 in. drive carrier Ultrastar SS530 SAS 12Gb/s RI-1DW/D 1.92TB 1EX2034 w/ 3.5 in.
  • Page 33 3.5 in. to 2.5 in. drive carrier Ultrastar SS530 SAS 12Gb/s RI-1DW/D 15.36TB 1EX2097 w/ 3.5 in. to 2.5 in. drive carrier Table 26: Western Digital Ultrastar SS540 Part Drive Type Interface Drive Writes Encryption Volume Number Ultrastar SS540...
  • Page 34 1. Overview Installation Guide 1.8 List of Compatible Drives Part Drive Type Interface Drive Writes Encryption Volume Number Ultrastar SS540 SAS 12Gb/s RI-3DW/D 3.2TB 1EX2665 w/ 3.5 in. to 2.5 in. drive carrier Ultrastar SS540 SAS 12Gb/s RI-3DW/D 3.2TB 1EX2666 w/ 3.5 in.
  • Page 35 1. Overview Installation Guide 1.8 List of Compatible Drives Table 27: Western Digital Ultrastar SA620 Part Drive Type Interface Drive Writes Encryption Volume Number Ultrastar SA620 No longer SSD SATA 6Gb/s RI-1.8DW/D 400GB w/ 3.5 in. to 2.5 in. drive carrier...
  • Page 36 1. Overview Installation Guide 1.8 List of Compatible Drives Drive Type Form Factor Interface Encryption Volume Part Number Sandisk X600 M.2 M.2 2280 SATA 6Gb/s 128GB 1EX1574 Sandisk X600 M.2 M.2 2280 SATA 6Gb/s — 256GB 1EX1570 Sandisk X600 M.2 M.2 2280 SATA 6Gb/s 256GB...
  • Page 37: Chapter 2. Disclaimers

    Western Digital Disclaimers Learn about the Regulatory, Safety, and Electromagnetic standards for which this product is compliant. The following chapter describes the Regulatory Statement of Compliance, Safety Compliance, and Electromagnetic Compatibility Agency Requirements for the Ultrastar Serv60+8 . In This Chapter: - Restricted Access Location......
  • Page 38: Restricted Access Location

    2. Disclaimers Installation Guide 2.1 Restricted Access Location 2.1   Restricted Access Location The Ultrastar Serv60+8 is intended for installation in a server room or computer room where at least one of the following conditions apply: • access can only be gained by service persons or by users who have been instructed about the restrictions applied to the location and about any precautions that shall be taken and/or •...
  • Page 39: Country Certifications

    2. Disclaimers Installation Guide 2.4 Country Certifications • EN 61000-4-3 Radiated Immunity • EN 61000-4-4 EFT • EN 61000-4-5 Surge • EN 61000-4-6 RF Common Mode • EN 61000-4-8 Power Frequency Magnetic Field • EN 61000-4-11 Voltage Dips and Interruptions 2.4  ...
  • Page 40: Chapter 3. Safety

    Western Digital Safety The following chapter provides safety and regulatory information for the Ultrastar Serv60+8 . In This Chapter: - Safety Warnings and Cautions....34 - Electrostatic Discharge........34 - Optimizing Location........34 - Power Connections........35 - Power Cords..........35 - Rackmountable Systems......35...
  • Page 41: Safety Warnings And Cautions

    3.2   Electrostatic Discharge CAUTION Electrostatic discharge can harm delicate components inside Western Digital products. Electrostatic discharge (ESD) is a discharge of stored static electricity that can damage equipment and impair electrical circuitry. It occurs when electronic components are improperly handled and can result in complete or intermittent failures.
  • Page 42: Power Connections

    3. Safety Installation Guide 3.4 Power Connections Position the unit so that there is adequate space around it for proper cooling and ventilation. Consult the product documentation for spacing information. Keep the unit away from direct strong magnetic fields, excessive dust, and electronic/electrical equipment that generate electrical noise.
  • Page 43: Safety And Service

    All maintenance and service actions appropriate to the end-users are described in the product documentation. All other servicing should be referred to a Western Digital-authorized service technician. To avoid shock hazard, turn off power to the unit by unplugging both power cords before servicing the unit.
  • Page 44: Chapter 4. Packaging

    Western Digital Packaging The following chapter provides information about how the Ultrastar Serv60+8 is packaged and instructions for unpacking In This Chapter: - Ultrastar Serv60+8 Packaging Overview............38 - Ultrastar Serv60+8 Unpacking Procedure............41...
  • Page 45: Ultrastar Serv60+8 Packaging Overview

    4. Packaging Installation Guide 4.1 Ultrastar Serv60+8 Packaging Overview 4.1   Ultrastar Serv60+8 Packaging Overview Figure 7: Outer Packaging The Ultrastar Serv60+8 is shipped in protective The inner contents of the Ultrastar Serv60+8 outer packaging that consists of cardboard caps on packaging consists of three layers: the accessory the top and bottom and an outer sleeve surrounding tray (top), the chassis box (middle), and the drive...
  • Page 46 4. Packaging Installation Guide 4.1 Ultrastar Serv60+8 Packaging Overview Accessory Tray The accessory tray contains boxes for the CMA arm, the Rails, and the Top Cover Alignment Brackets, as well as plastic bags containing the cables and necessary hardware. Figure 8: Accessory Tray Contents Table 31: Accessory Tray Contents Container Contents...
  • Page 47 4. Packaging Installation Guide 4.1 Ultrastar Serv60+8 Packaging Overview Chassis Box The Chassis is boxed in the middle layer and protected by foam padding. It comes with pre-installed System Fans, PSUs, and an IOM . Figure 9: Chassis Box Contents Table 32: Chassis Box Contents Container Contents...
  • Page 48: Ultrastar Serv60+8 Unpacking Procedure

    4. Packaging Installation Guide 4.2 Ultrastar Serv60+8 Unpacking Procedure 4.2   Ultrastar Serv60+8 Unpacking Procedure Step 1 : Make sure that all of the necessary parts and equipment are available, including any equipment necessary to support the enclosure during installation. To verify the list of necessary parts, see Ultrastar Serv60+8 Packaging Overview (page 38).
  • Page 49 4. Packaging Installation Guide 4.2 Ultrastar Serv60+8 Unpacking Procedure Figure 12: Unpack Accessory Tray Contents Step 5 : Open the chassis box and remove the top cushions from the front and rear of the chassis. Figure 13: Unpack Chassis Box Contents Step 6 : With assistance, and without using the system handles, remove the chassis from the chassis box and set it aside.
  • Page 50 4. Packaging Installation Guide 4.2 Ultrastar Serv60+8 Unpacking Procedure Caution: Do not lift the chassis by the system handles. The handles are designed only for sliding the enclosure out of the rack on its rails. Step 7 : Open the drive boxes and verify their contents. Depending on the version of the Ultrastar Serv60+8 being unpacked, four boxes should contain fourteen drive assemblies (in the form of HDDs, SSDs, or blanks), one box should contain four drive assemblies, and one box should contain eight SSD assemblies.
  • Page 51: Chapter 5. Installation

    Western Digital Installation In This Chapter: - Installation Overview........45 - Rails Installation..........46 - Chassis Installation........57 - CMA Installation........... 60 - Cable Installation......... 62 - Top Cover Installation and Extension Test..............66 - Drive Installation.......... 68 - Shipping Screws Installation....... 73...
  • Page 52: Installation Overview

    5. Installation Installation Guide 5.1 Installation Overview 5.1   Installation Overview Procedure Info # of People Time Required Tools Required Parts Required Required 3 Total (2 for 45 min. • Long T15 Torx Screwdriver • Option 1:M5 x 12mm T15 Flat Team Lifting Head Torx screws and included •...
  • Page 53: Rails Installation

    5. Installation Installation Guide 5.2 Rails Installation • Toolless installation CMA Lite: • Smaller rack footprint for shallower racks and/or racks with doors • Manages and protects a lighter cable load (with only one CMA arm) during installation, operation, and servicing •...
  • Page 54 5. Installation Installation Guide 5.2 Rails Installation Note: There are Right and Left rails and they must be installed as a set. Each inner rail will read "R" for the right or "L" for the left embossed on the inside. Each outer rail will read "R-Front"...
  • Page 55 5. Installation Installation Guide 5.2 Rails Installation Figure 16: Inner Rail Attachment c. Slide the inner rail toward the rear of the chassis to lock it in place. There will be an audible click and the mounting pegs will cover the front part of the keyhole. Figure 17: Slide Inner Rail Caution: When installing the inner rail onto the chassis, make sure to only use the special Low-Profile M4 x 3.2mm Philips screws provided in the accessory...
  • Page 56 5. Installation Installation Guide 5.2 Rails Installation Step 4 : Install the outer rails into the rack. Pay special attention to which side is being installed. The embossed R is for the right side and L is for the left side. Right and Left refer to when you are facing the front of the rack.
  • Page 57 5. Installation Installation Guide 5.2 Rails Installation Figure 19: Front Rail Release Clip Operation g. Use a level to make sure that the rails are aligned properly. h. Follow these steps for the other outer rail. Step 5 : Install the rail mounting hardware, starting with the uppermost rack mounting hole of the 4U space on the front of the rack.
  • Page 58 5. Installation Installation Guide 5.2 Rails Installation Figure 20: Cage Nut Spacing CMA Lite: a. Line the spacer bracket up with the bottom of rack unit location of the installed outer rails. The bottom of the spacer bracket will rest on top of the bottom outer rail pin.
  • Page 59 5. Installation Installation Guide 5.2 Rails Installation Figure 21: Spacer Bracket Orientation Figure 22: Spacer Bracket Placement b. Slide the nut plate down over the mounting pin on the back of the spacer bracket.
  • Page 60 5. Installation Installation Guide 5.2 Rails Installation Figure 23: Rack Spacer Nut Plate Installation c. Using a T15 Torx screwdriver, tighten the top captive screw to secure the mounting plate in place. Tighten the remaining captive screws at the bottom of the spacer bracket, and torque all four of the captive screws to 3.38-3.61 Nm / 30-32 in-lbf.
  • Page 61 5. Installation Installation Guide 5.2 Rails Installation a. From the rear of the rack, orient the alignment brackets so that the groove that will catch the cover is facing the inside of the rack. Figure 25: Alignment Bracket Groove (highlighted in red) b.
  • Page 62 5. Installation Installation Guide 5.2 Rails Installation Figure 26: Rear Screws Installation Caution: Be careful to set the screws properly in the cover alignment bracket and rail to prevent crossthreading. Option2: Using a Long T15 Torx Screwdriver, install the screw plate to attach the rear cover alignment bracket and the rear rail to the rack posts.
  • Page 63 5. Installation Installation Guide 5.2 Rails Installation Figure 27: Screw Plate Installation Step 7 : CMA Standard: Install the two rack latch brackets at the front of the rack. a. Orient the brackets so that the screw holes are between the two pins supporting the outer rails as shown in the following image.
  • Page 64: Chassis Installation

    5. Installation Installation Guide 5.3 Chassis Installation Figure 28: Rack Latch Bracket Installed b. Use 6 of the included M5 x 12mm screws and the T15 Torx screwdriver to install each bracket, 3 screws per bracket.   W hat to do next:   T he rails are now installed. Proceed to Chassis Installation (page 57).
  • Page 65 5. Installation Installation Guide 5.3 Chassis Installation Time: 10 minutes Caution: Always install the top cover onto the enclosure before installing the chassis into a rack. Not having the top cover installed may damage the alignment brackets. Step 1 : Extend the mid-rails out of the rack so that they are protruding from the front of the rack and the safety latches engage.
  • Page 66 5. Installation Installation Guide 5.3 Chassis Installation Figure 30: Bearing Plate Caution: This step in the installation requires a minimum of 3 individuals to install safely, two to lift and one to guide the others who may have difficulty seeing because the enclosure is in the way. Ensure that the appropriate measures are taken to safely support the enclosure during installation.
  • Page 67: Cma Installation

    5. Installation Installation Guide 5.3 Chassis Installation Figure 31: Installing the Chassis d. Once the rails are mated properly, slide the enclosure into the rack until it is stopped by the safety catch on the rails. Push the release lever on the safety latch (located on the side of each of the rails), and push the enclosure the rest of the way into the rack.
  • Page 68 5. Installation Installation Guide 5.4 CMA Installation 5.4   CMA Installation This procedure provides instructions for installing the cable management assembly for an Ultrastar Serv60+8 . Before you begin: Complete the instructions in Chassis Installation (page 57). Table 36: Installation Requirements Tool(s): N/A Part(s): CMA Standard Arm 1EX1174 (single)
  • Page 69: Cable Installation

    5. Installation Installation Guide 5.5 Cable Installation Figure 33: CMA Orientation c. Slowly slide the enclosure forward to ensure the arm is operating properly, then slide it back into the rack.   W hat to do next:   T he cable management assembly is now installed. Proceed to Cable Installation (page 62).
  • Page 70 5. Installation Installation Guide 5.5 Cable Installation Figure 34: Open Baskets c. Route all of the cables being connected to the enclosure through the open baskets. d. Close all of the baskets. e. If the Ultrastar Serv60+8 is being installed in a rack and will subsequently be transported inside that rack, it is important to use the included cable tie to wrap the CMA bundle to ensure it does not get damaged during transport.
  • Page 71 5. Installation Installation Guide 5.5 Cable Installation Figure 35: Open Baskets c. Gather the SAS, power, and Ethernet cables for installation. Note: Route all cables to IOM A (left hand side looking at the rear). d. Route all of the cables being connected to the enclosure through the open baskets. e.
  • Page 72: Cabling For Cma Standard And Cma Lite

    5. Installation Installation Guide 5.5 Cable Installation   W hat to do next:   T he data and power cables are now installed. Proceed to Top Cover Installation and Extension Test (page 66). 5.5.1   Cabling for CMA Standard and CMA Lite 5.5.1.1  ...
  • Page 73: Top Cover Installation And Extension Test

    5. Installation Installation Guide 5.5 Cable Installation In this case, the first measurement from the tip of the cable to the first velco strip is 6in. Followed by a 12in. measurement to the CMA cage. There is no need for a B value due how short this configuration is. 5.5.1.2  ...
  • Page 74: Top Cover Installation And Extension Test

    5. Installation Installation Guide 5.6 Top Cover Installation and Extension Test 5.6   Top Cover Installation and Extension Test This procedure provides instructions for installing the top cover and performing an enclosure extension test for an Ultrastar Serv60+8 . Before you begin: Complete the instructions in Cable Installation (page 62).
  • Page 75: Drive Installation

    5. Installation Installation Guide 5.7 Drive Installation Figure 39: Chassis Handle Operation Step 4 : Perform this same action two more times without the drives loaded to make sure the rail kits are installed properly.   W hat to do next:   T he top cover is now installed, and extension of the enclosure for servicing has been tested.
  • Page 76 5. Installation Installation Guide 5.7 Drive Installation Figure 40: LED Pointer Orientation c. Align the drive with the empty slot that will receive it. Lower it into the slot, making sure it stays level and does not snag.
  • Page 77 5. Installation Installation Guide 5.7 Drive Installation Figure 41: Installing a 3.5in HDD Assembly d. Pinch the latch release and carefully press downward to seat the 3.5in HDD Assembly the rest of the way. Step 2 : Repeat the preceding steps to install each subsequent drive assembly using the same method as the first, populating the enclosure from left-to-right, rear-to-front.
  • Page 78: Operating The 2.5" Drive Carrier

    5. Installation Installation Guide 5.7 Drive Installation Figure 42: Drive Layout Caution: To ensure proper airflow for enclosure cooling, all drive slots must be populated with either drives or drive blanks. Step 3 : Now that the drives are installed into the chassis, test the installation by sliding the enclosure in and out of the rack a minimum of three times.
  • Page 79 5. Installation Installation Guide 5.7 Drive Installation Figure 43: Clamp Release (clamp shown in blue for visual clarity) Step 2 : Slide the clamp in the direction shown in the following image to loosen it from the drive. Be sure not to slide too far as this will allow the clamp to fall from the carrier body and it will have to be reinstalled.
  • Page 80: Shipping Screws Installation

    5. Installation Installation Guide 5.8 Shipping Screws Installation Figure 45: Clamp Pins (clamp shown in blue for visual clarity) 5.8   Shipping Screws Installation This procedure provides instructions for securing an Ultrastar Serv60+8 to the rack for shipping. Before you begin: Complete the instructions in Drive Installation (page 68).
  • Page 81: Enclosure Power On

    5. Installation Installation Guide 5.9 Enclosure Power On Figure 46: Shipping Bracket Screw Locations Figure 47: Shipping Bracket Screw Locations (CMA Lite)   W hat to do next:   T he shipping screws are now installed. Proceed to Enclosure Power On (page 74).
  • Page 82 5. Installation Installation Guide 5.9 Enclosure Power On Part(s): N/A Person(s): 1 Time: 5 minutes Step 1 : Plug the enclosure power cords into a PDU. Caution: The Ultrastar Serv60+8 can only be plugged into high line (200 - 240 VAC) power. If the unit is plugged into low line (110-127 VAC), the PSU will report a "Critical"...

Table of Contents