Operation
8.1.2.5

"STOP" operating status

In "STOP" operating status
No user program is run.
}
It is possible to communicate with the motion controller in the terminal program via the
}
command language.
Status of LED:
The LED is lit continuously.
}
8.1.2.6

"Fatal Error" operating status

"Fatal Error" operating status is reached when an error occurs.
The operating status is adopted temporarily.
}
The motion controller automatically changes back to "Startup" operating status.
}
The error is entered in the error stack.
}
Status of LED:
The LED is switched off.
}
8.1.3

Change in operating status

0
-->
The system changes to "Power Off" operating status when the 24 VDC supply voltage has
been switched off.
0
The system changes to "Startup" operating status when the 24 VDC supply voltage has
been switched on.
1
The LED lights for 4 s if "Startup" has been run without error.
Press the reset button during this time to change to "Boot Menu" operating status.
}
1
"Startup" operating status has been run without error. The system changes to "RUN" status
if a user program was loaded in "Startup" status.
1
"Startup" operating status has been run without error. The system changes to "STOP"
status if no user program was loaded in "Startup" status.
1
The system changes to "Fatal Error" status if an error occurred in "Startup" status.
Operating instructions PMCprimo C
1002242-EN-03
All operating states change to "Power Off"
1
-->
Change from "Power Off" to "Startup"
2
-->
Change from "Startup" to "Boot Menu"
3
-->
Change from "Startup" to "RUN"
4
-->
Change from "Startup" to "STOP"
5
-->
Change from "Startup" to "Fatal Error"
49