Wiring

6
Wiring
6.1

Wiring guidelines

Please note:
Cable cross sections for field connection terminals in mm
}
Inputs
Appropriate wiring must be used to exclude short circuits between the inputs or to a
}
supply line.
Cables must be shielded if the signals are used as reference inputs. Other signal lines
}
do not need to be shielded.
Outputs
If short circuits occur between the cable from the output to the load and a supply line, it
}
will no longer be possible to switch off the load.
Possible remedy: Use separate multicore cable for supply voltages.
Use appropriate wiring to exclude short circuits between the outputs.
}
The actuators may be connected using unshielded cables.
}
The outputs do not need suppression for inductive loads.
}
Cable material
Use copper wiring.
}
Operating instructions PMCprimo C
1002242-EN-03
Digital inputs/outputs, supply voltage: 0.5 (AWG20) ... 1.0 (AWG18), AEH without
plastic collar, in accordance with DIN 46228/1
: