12. Connect the serial port cable to the M.2 SSD/dedicated iLO/serial port enablement board.
To prevent the serial port cable from blocking the system fan airflow, route the cable beneath the fan, and then
secure the extra length of the cable in the serial port cable clip.
13. If removed, install the air baffle.
14. Install the access panel.
15. Install the front bezel.
16. Do one of the following:
If the server is in tower mode: Position the tower server for operation.
If the server is in rack mode: Install the server on the tray.
17. Connect all peripheral cables to the server.
18. Connect the power cords:
a. Connect each power cord to the server.
b. Connect each power cord to the power source.
19. Power up the server.
The installation is complete.

Enabling the dedicated iLO management module

The onboard NIC 1/shared iLO connector is set as the default system iLO connector. To enable the dedicated iLO
management module, use the iLO 5 Configuration Utility accessible within the HPE UEFI System Utilities.
For more information on the UEFI System Utilities, see the UEFI documentation on the Hewlett Packard Enterprise
website (http://www.hpe.com/servers/uefi).
IMPORTANT: If the iLO configuration settings are reset to the default values, remote access to the machine will be
lost. Access the physical machine and repeat the procedure described in this section to re-enable the dedicated iLO
management connector.