Specifications; Environmental Specifications; Server Specifications; Power Supply Specifications - HPE ProLiant ML30 Gen10 User Manual

Hide thumbs Also See for ProLiant ML30 Gen10:
Table of Contents

Advertisement

Specifications

Environmental specifications

Specification
Temperature range
Operating
Nonoperating
Relative humidity (noncondensing)
Operating
Nonoperating
1
All temperature ratings shown are for sea level. An altitude derating of 1.0° per 304.8 m (1.8°F per 1000 ft) to 3048 m (10,000 ft) is
applicable. No direct sunlight allowed.
For certain approved hardware configurations, the supported system inlet temperature range is extended:
5°C to 10°C (41°F to 50°F) and 35°C to 40°C (95°F to 104°F) at sea level with an altitude derating of 1.0°C per every
175 m (1.8°F per every 574 ft) above 900 m (2953 ft) to a maximum of 3050 m (10,000 ft).
40°C to 45°C (104°F to 113°F) at sea level with an altitude derating of 1.0°C per every 125 m (1.8°F per every 410
ft) above 900 m (2953 ft) to a maximum of 3048 m (10,000 ft).

Server specifications

Specification
Height
Depth
Width
Weight (maximum load, approximate values)
Four-bay LFF non-hot-plug drive model
Four-bay LFF hot-plug drive model
Eight-bay SFF hot-plug drive model

Power supply specifications

Depending on the installed options and the regional location where the server was purchased, the server can be
configured with one of the following power supplies:
1
Value
10°C to 35°C (50°F to 95°F)
-30°C to 60°C (-22°F to 140°F)
10% to 90%
28°C (82.4°F) maximum web bulb temperature
5% to 95%
38.7°C (101.7°F), maximum wet bulb temperature
Value
36.83 cm (14.50 in)
47.50 cm (18.70 in)
17.50 cm (6.89 in)
15.24 kg (33.59 lb)
17.60 kg (38.80 lb)
15.50 kg (34.17 lb)
133
Specifications

Advertisement

Table of Contents
loading