HPE ProLiant ML30 Gen10 User Manual page 94

Hide thumbs Also See for ProLiant ML30 Gen10:
Table of Contents

Advertisement

Locate and download the latest ROM version from the Hewlett Packard Enterprise Support Center website.
Follow the instructions on the website to update the system ROM.
3.
Power down the server.
4.
Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
5.
Disconnect all peripheral cables from the server.
6.
Do one of the following:
If the server is in tower mode: Position the tower server for hardware configuration.
If the server is in rack mode: Remove the server from the rack.
7.
Remove the front bezel.
8.
Remove the access panel.
9.
If installed, remove the air baffle.
10. Remove any components or cables that may prevent access to the TPM connector.
11. Proceed to Installing the TPM board and cover.
Installing the TPM board and cover
Procedure
1. Observe the following alerts:
CAUTION: If the TPM is removed from the original server and powered up on a different server, data stored in
the TPM including keys will be erased.
CAUTION: The TPM is keyed to install only in the orientation shown. Any attempt to install the TPM in a
different orientation might result in damage to the TPM or system board.
2. Align the TPM board with the key on the connector, and then install the TPM board. To seat the board, press the TPM
board firmly into the connector. To locate the TPM connector on the system board, see the server label on the access
panel.