Pso Opto Output (J7); Figure 2-26: Pso Output Sources Current; Figure 2-27: Pso Output Sinks Current; Table 2-23: Pso Output Polarity Settings For Jp16 - Aerotech Npaq DL 4010 Series Hardware Manual

Table of Contents

Advertisement

Npaq® Hardware Manual

2.7.1. PSO Opto Output (J7)

The PSO OPTO OUT is electrically isolated and does not require an external power source to operate. The
output may be used to source (or sink) current (as shown in
By default, JP16 is installed in the 1-2 position for normally open operation. If the PSO-NC option is ordered,
JP16 is installed in the 2-3 position giving normally-closed operation. This mode should be used with caution
since the Npaq cannot maintain the closed state when its AC mains power is turned off. The PSO-NC (JP16
2-3 setting) should not be used when fail-safe operation is required. JP16 jumper settings are shown in
2-23. Refer to
Figure 4-3
Table 2-23:
PSO Output Polarity Settings for JP16
PSO Output Polarity
Normally Open
Normally Closed
Table 2-24:
Output Specifications 
Description
Maximum Voltage
Current
Latency
Maximum Frequency
Figure 2-26:
PSO Output Sources Current
60
for the JP16 jumper location.
Chapter 2
Installation and Configuration
Figure 2-26
and
Figure
2-27).
JP16 Setting
1-2 * (Recommended)
2-3
Specification
24 V
250 mA
120 ns
12.5 MHz
Figure 2-27:
PSO Output Sinks Current
www.aerotech.com