MAINTENANCE
If the air cleaner clogging caution lamp (1) lights up, clean the
air cleaner element.
METHOD FOR CLEANING AIR CLEANER OUTER ELEMENT
Do not use a screwdriver or other tool.
Do not knock the body of the air filter to clean it.
Do not use compressed air to clean the air filter body as it may damage the secondary element.
1.
Open the cover (1).
2.
Remove the cover (2).
3.
Extract the primary element (3).
NOTICE
Do not remove the secondary element (4). If it is
removed, dirt may enter and damage the engine.
k
k
WARNING
WENAM00130
MAINTENANCE PROCEDURE
RKA65050
RKA65030
RKA65040