PROCEDURE FOR MANUAL STATIONARY REGENERATION
When the manual stationary regeneration is required, check if
the caution lamp (1) is lit.
During manual stationary regeneration, there are times when
engine low idle speed increases automatically.
1.
Move the machine to a safe area and stop it with the en-
gine running.
2.
Make sure there are no persons or combustible materials
around the exhaust pipe outlet and aftertreatment devices.
3.
Set the lock lever securely in LOCK position (L).
4.
Set the fuel control dial to Low idle (MIN) position.
5.
Press the F6 key to display: "Aftertreatment Devices Re-
generation"
6.
Select manual stationary regeneration, and push F6.
If the screen shown in the figure does not change after you
push F6 in Procedure 6, recheck procedures 1 through 5, and
then push switch F6 again.
WENAM00130
EXPLANATION OF COMPONENTS
RKA63300
3-135