3-7 Setting the Side Glue Rollers

When you change the binding type, (binding with covers or
binding without cover on the Binding Mode Screen, the
screen with the message reminding you to set or release
the side glue rollers will appear. Set or dislocate the side
guide rollers according to the binding type.
When binding with covers
The screen will tell you to set the side glue roller on the
far side.
Turn off the power switch and open
the left safety cover.
Wear thick gloves during this opera-
tion. The melt tank may be heated to
200 degrees Celsius (400 Fahrenheit)
and may cause severe skin burns.
To adjust the side gluing roller on
the far side, loosen the locking
screw on the positioning plate and
turn the plate counterclockwise to
the memorized position.
Side Gluing Roller (far side)
Tighten the locking screw.
CAUTION
Allen Wrench
Locking Screw
Positioning Plate
When binding without covers
The screen will tell you to dislocate the side glue roller
on the far side.
Before dislocating the roller, make sure to
memorize the original setting position.
Turn off the power switch and open
the left safety cover.
Wear thick gloves during this opera-
tion. The melt tank may be heated to
200 degrees Celsius (400 Fahrenheit)
and may cause severe skin burns.
To adjust the side gluing roller on
the far side, loosen the locking
screw on the positioning plate and
turn the plate clockwise to the stop.
Tighten the locking screw.
- The pre-sets for the binding operation are
complete. Start the binding operation, refer-
ring to [Start Binding] on next page.
44
CAUTION
Side Gluing Roller (far side)
Allen Wrench
Locking Screw
Positioning Plate