4-9 Side Glue Amount Adjustment (Far Side)
WARNING
Wear thick gloves during this operation.
The glue amount adjusting plate is very
hot, and may cause severe skin burns.
Loosen the two mounting screws
on the glue amount adjusting plate.
- The illustration below shows the glue amount
adjust plate on the far side.
Mounting Screws
Glue Amount Adjusting Plate
Adjust the position of the glue
amount adjusting plate.
- Move the glue amount adjust plate left or right
to adjust the glue amount on the application
roller.
- Move the plate to the left to increase
the glue amount.
- See the inside of the application roller
(shown in the illustration below) to
adjust the glue amount.
Mounting Screws
The gap here controls the
amount of glue applied.
Lock the mounting screws on the
glue amount adjusting plate and
close the left safety cover.