7-1
Weekly Timer
Weekly Timer Operation Procedures
Switch Description
- If the starting time for the melt tank heat-
ing is set beforehand, the binding opera-
tion can be started without waiting for the
glue to be melted.
- When using the weekly timer, leave the
main power switch turned ON.
- If the power switch for the main body of
BQ-270 is not turned on for over 300 hours,
the Sunday (S) lamp may blink when the
power switch is turned on. In this case, set
the current time and day. (Refer to the next
page)
Reset Lamp
When this timer does not work correctly
according to setting, reset lamp illuminates.
Setting Scale
This scale is used to set the time to
turn the BQ-270 ON or OFF. One
rotation takes a day and the indexes
can be set every 15 minutes. Set the
tabs inside to turn on the setting.
Current Time Setting Knob
This knob is used to set the current
time. One rotation of this knob takes
an hour.
Minutes Scale
Hours Scale
Day Select Switch
For each day on which the melt tank
will be heated automatically, set the
switch for that day to [AUTO].
For each day on which the melt tank
will not be heated automatically, set the
switch for that day to [OFF].
NORMAL
A-TB72CQ
RESET
OFF
DAY
SETTING
PRESENT
TIME
OFF
OFF
ON
AUTO
98
Continuous / Normal Switch
Set this switch to "CONTINUOUS" when
the time between turning the machine on
and off is over 24 hours.
Normally, set this switch to [NORMAL].
CON-
Output Lamp
TINUOUS
This lamp lights when the timer function
OUTPUT
is active.
AUTO
S
Day Lamps
M
These lamps are used to indicate the
T
current day. A lighted lamp indicates
W
T
the current day.
F
Current Day Setting Button
S
This button is used to select the current day.
ON
AUTO
ON, Auto, and OFF Switch
ON: When the main power switch of the BQ-270
is turned on, the melt tank is always heated
up, independently of the timer function.
AUTO: The timer function is available.
OFF: Although the main power switch of the
BQ-270 is turned on, power is not supplied
to the BQ-270.