Loading Configuration From The Station To The Pc; Creating A Backup Of The 'Site' Configuration - Siemens FS720 Commissioning, Maintenance, Troubleshooting

Fire detection system
Table of Contents

Advertisement

Connectivity and communication with 'Station'
4

Loading configuration from the station to the PC

4.8 Loading configuration from the station to the PC

4.9 Creating a backup of the 'Site' configuration

32 | 178
Building Technologies
Fire Safety
The 'Upload site' function can be used to load the configuration of a ↑ 'Site' to
Cerberus-Engineering-Tool on the PC.
w The 'Site' is opened in Cerberus-Engineering-Tool.
w The PC is connected to the ↑ 'Station'.
w 'Station' and Cerberus-Engineering-Tool have the same 'Site' ID.
w 'Station' and Cerberus-Engineering-Tool are part of the same sales channel.
1. Select 'Commissioning' > 'Upload site'.
a The 'Upload site' and 'Connect' windows are opened.
2. Select the connection in the 'Connect' window and click on 'OK'.
a The 'Stations' are listed in the 'Upload site' window.
3. Select the 'Stations' whose configuration you would like to load to Cerberus-
Engineering-Tool and click on 'Start'.
a The 'Action confirmation' window opens.
4. Click on 'Yes'.
a The configuration is loaded to the PC.
a The progress is displayed in the 'Upload site' window.
With the 'Create backup embedded configuration' function, you can create a
backup file of the ↑ 'Site' configuration.
The following conditions must be satisfied for a complete backup:
All of the ↑ 'Stations' in the 'Site' must be networked and commissioned.
The 'Site' IDs for all 'Stations' must match the 'Site' ID for the 'Site' loaded in
Cerberus-Engineering-Tool.
The ↑ BDVs for all 'Stations' must be compatible with the BDV for the 'Site'
loaded in Cerberus-Engineering-Tool.
The BDVs are compatible when the major version and the minor version
are identical. The bugfix version is not relevant for the compatibility. The
versions are saved in the BDV file name. You will find more information on
the format of the BDV file name in document A6V10210424.
The country codes of the BDVs for all 'Stations' must match the BDV for the
'Site' loaded in Cerberus-Engineering-Tool.
You will find Information about BDV names and versions in document
A6V10210424. See chapter 'Applicable documents'.
If the above-mentioned conditions are not satisfied, a corresponding message is
displayed and an incomplete backup file created. In this instance, 'incomplete' is
added to the file name of the backup file.
A6V10210416_j_en_--
2018-08-29

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents