DESCRIPTIONS

SYSTEM DESCRIPTION

The FS-100 is an advanced modular fire alarm control unit.
It features addressable/analog detection,
programming, and memory capability. Its base configuration includes one addressable device circuit, with
four conventional notification appliance circuits.
The basic FS-100 control unit mounts in a 14-3/8" x 14-3/8" back-box with overall cover size of 14-3/4" x
14-21/32". Operating controls and indicators are mounted inside a secure door. An 80-character LCD
display provides specific indications for addressable devices while LEDs indicate general panel status.
Semi-flush mounting kits are available for the enclosure.

HARDWARE CONFIGURATION

The main board mounts in the rear of the enclosure. The power supply is physically contiguous with the
main board.
The FS-100 main board provides the interface for external analog system connections, for
the addressable device circuit, four notification appliance circuits, remote signaling and indicating
interfaces, and connection of the main system power supply. Optional boards mount on the main board.
The display board mounts on the front plate, allowing it to carry the controls and displays which must be
accessible.
All normal operation is controlled from the front of the control unit via push-button switches. Displays are
provided by an 80-character, alphanumeric, backlit LCD display and by discrete LED indicators for major
control unit functions.
The 80-character LCD display is used to display event data, including alarms and troubles, identification
of zone or device, and presentation of history.
The display is controlled by a set of four push-button
switches commanding the control processor. A back light is included in the display to assure visibility in
low light, but to conserve power, it is only activated during a reported event or on operation of a display
control switch.
Individual LEDs on the panel are provided to indicate SYSTEM ALARM, PREALARM, SUPERVISORY,
ALARM SILENCED, SYSTEM TROUBLE and AC POWER ON. Direct push-button controls are provided
for ALARM SILENCE, TROUBLE SILENCE/ACKNOWLEDGE, MENU and SYSTEM RESET.
3