M108S, WSM
(1) Modulating Valve
(2) Proportionally Reducing Valve
(3) Shuttle Shift Spool (Forward,
Reverse)
(4) Accumulate Valve
When the shuttle lever is moved to "REVERSE" or "FORWARD", pressure-fed oil from P port flows into shuttle
clutch via R or F port. At this time, the pressure of R or F port is increased gradually by modulating valve (1).
When the shuttle clutch is engaging, the accumulate valve (4) assists the operation of modulating valve (1) to
reduce a shock.
(5) Shuttle Valve
(6) Inching Valve
(7) Shuttle Lever
(8) Clutch Pedal
A : Check Port (Modulation)
B : Check Port (Reverse)
C : Check Port (Forward)
D : Check Port (Pump)
F : To Clutch Body (Forward)
R : To Clutch Body (Reverse)
P : From Regulator Valve
C1, C2 : Connection Port
3-M8
TRANSMISSION
T1 to T5: To Transmission Case
N1 : Port N1
N2 : Port N2
a :
Connect to Shuttle Lever
b :
Connect to Clutch Pedal
KiSC issued 06, 2007 A