Keysight E1458A Command Reference
Example
MEAS:DIG:DATA0:WORD:TRACe first_block reads 16-bit data from port 0 and
stores it in the predefined user memory location first_block.
MEASure:DIGital:FLAGn?
MEASure:DIGital:FLAGn? reads the status of the flag line on port n and returns a
0 or 1 to show whether a peripheral has set the flag line to READY or BUSY.
Parameters
Comments
Example
MEAS:DIG:FLAG1? reads the port1 flag line.
70
–
Input data is returned in decimal format. Other formats are not supported
for input, however data output may be in binary, octal, decimal or
hexadecimal.
–
The keyword LW32 may be used instead of LWORd.
–
:DATAn is the keyword used for commands relating to the data at port n.
The port number n must be the last character of the keyword without
spaces.
–
Related Commands: MEASure:DIGital:DATAn[:VALue]?
SOURce:DIGital:TRACe:DEFINE <name>
–
*RST Condition: Set to input on all ports.
Parameter Name
Parameter Type
FLAGn
Numeric
–
MEASure:DIGital:FLAGn? is used to implement custom handshakes. The
handshake mode must be set to NONE to use this command.
–
:FLAGn is the keyword used for commands relating to the flag line at port
n. The port number n must be the last character of the keyword without
spaces.
–
If n is omitted FLAG0 is used.
–
MEASure:DIGital:FLAGn? may be affected by the condition of the flag
combining jumpers. Refer to Chapter 2 for additional information.
–
Related Commands: [SOURce:]DIGital:CONTroln:POLarity?
[SOURce:]DIGital:CONTroln[:VALue] [SOURce:]DIGital:FLAGn:POLarity
[SOURce:]DIGital:FLAGn:POLarity?
Range of Values
none, 0 through 11
Keysight E1458A 96-Channel Digital I/O Module User Guide
MEASure Subsystem
Default
0