Specifications

Logic Levels:
TTL Compatible, 5V max
Data Lines:
Iout (High): -5.2 mA
@ Vout (High): 2.5 V (Pullup Enabled)
Iout (Low): 48 mA
@ Vout (Low): 0.5V
Vin (High): >2.0 V; <5.0 V Vin (Low): <0.8 V
Iin (High): <2.5 mA @ 2.5 V Iin (Low): <3.2 mA @ 0.4 V
Handshake Lines:
Iout (High): 250 µA
@ Vout (High): 5 V Iout (Low): 40 mA
@ Vout (Low): 0.7 V Iout (Low):16 mA
@Vout (Low): 0.4V Vin (High): >2.0V Vin (Low): <0.8 V Iin
(Low): <1.75 mA
Module Size/Device Type:
C, register based
Connectors Used: P1, P2
Number of Slots: 1
VXIbus Interface Capability:
Slave, interrupter, A16, D16, D08EO
Interrupt Level: 1-7, selectable
Typical Data Line Current vs. Data Line Voltage
Power Requirements:
Voltage: +5 V
Peak module current, IPM (A): 1.20
Dynamic module current, IDM (A): 0.01
Watts/Slot: 6.0
Cooling/Slot: 0.05 mm H2O @ 0.5 liter/sec
Humidity: 65%, 0 to 40?C Operating Temperature: 0
to 55?C Storage Temperature: -40 to 75?C
EMC, RFI, Safety:
meets FTZ 1046/1984, CSA 556B, IEC 348, UL 1244
Net Weight (kg): 1.0