DISPlay Subsystem
DISPlay Subsystem
The DISPlay subsystem turns on the monitor mode. Parameters related to the
state of the data and control lines are shown on the external terminal. Refer to
the C-Size VXIbus Systems Configuration Guide for supported terminal types.
The parameters displayed are:
Subsystem Syntax
DISPlay:MONitor:PORT
DISPlay:MONitor:PORT [<port>] sets the displayed port number.
Parameters
Comments
Keysight E1458A 96-Channel Digital I/O Module User Guide
–
port number
–
polarity
–
handshake mode
–
state of the control line
–
state of the flag line
–
values on the data lines
DISPlay
:MONitor
:PORT <port | AUTO>
:PORT? [<MAX | MIN | DEF>]
[:STATe] <OFF | ON>
[:STATe]?
Parameter
Parameter
Name
Type
<port>
Numeric or
Discrete
–
In the AUTO mode of operation, the display shows the state of the port
last programmed. MIN sets port 0. MAX sets port 11. No parameter or DEF
sets AUTO mode of operation.
–
Related Commands: DISPlay:MONitor[:STATe] DISPlay:MONitor:PORT?
–
*RST Condition: AUTO
Keysight E1458A Command Reference
Range of Values
none, 0 through 11
MIN | MAX | AUTO | DEF
Default
AUTO
63