5.2.3

Checking the acid level

The customer must check the acid level of the batteries once a week.
Warning
Risk of explosion and fire! When handling batteries, it is prohibited to
smoke and use an open fire.
Attention
• Observe the information in the operating manual of the battery
manufacturer!
• Refilling must only take place once the battery charging process
has been terminated.
Note
Batteries approved by Hako are equipped with an aquamatic
system.
C
Fig. 26:
Checking the acid level:
If the trough battery is equipped with an aquamatic system Fig. 26-A, each
individual cell features a sealing plug with float indicator.
The white dot must be located at the top and must be clearly visible. If this is
not the case, refill demineralised water according to DIN 43530-4.
Topping up with demineralised water:
Connect the end piece of the aquamatic system Fig. 26-B to a container with
demineralised water. Observe sufficient gradient, ensuring the water can flow
into the cells. Once the required filling level has been reached, the plugs
automatically seal the cells and indicate "full" Fig. 26-C.