Maintenance and Servicing
5.3.6

Checking the acid level

Warning
Risk of explosion and fire! When handling batteries, it is prohibited to
smoke and use an open fire.
Attention
• Observe the information in the operating manual of the battery
manufacturer!
• Refilling must only take place once the battery charging process
has been terminated.
Note
Batteries approved by Hako are equipped with an aquamatic
system.
Fig. 24:
The customer has to check the acid level of the battery weekly, demineralised
water (according to DIN 43530-4) must be refilled if necessary.
If the trough battery is equipped with an aquamatic system Fig. 24-A, each
individual cell features a sealing plug with float indicator. The white dot must
be located at the top and must be clearly visible. If this is not the case, refill
demineralised water.
To do so, connect the end piece of the aquamatic system Fig. 24-B to a
container with demineralised water. Observe sufficient gradient, ensuring the
water can flow into the cells. If the required level has been reached, the plugs
automatically seal the cells and indicate "full".