HAKO Scrubmaster B260 R Operating Manual page 61

Hide thumbs Also See for Scrubmaster B260 R:
Table of Contents

Advertisement

Service
Fault
code
2.3.5.1/
Side brushes stop
2.3.6.1/
2.3.6.4
Side brush arm lift sys-
tem stops
3.1.6.E
Cleaning function no
longer possible
3.2.6.6.
Service code indicator
when turning on the
machine
3.3.1.1
Service interval
expired
3.4.1.1
Speed control
3.4.1.2/
Driving not possible
3.4.1.4
3.4.5.1.
Cleaning function
switches off
3.6.6.4.
Driving and cleaning
not possible
4.2.1.4
Dosing system not
working
5.2.6.1
Faulty signal for charg-
ing state
measurement
7.1.5.1
USB connection not
working
03-7182-01.fm
Cause
Foreign particle blocks the
side brushes
Overloading or foreign
particles between side arm
and machine
Electrical defects
Discharged capacity of the
internal back-up battery of
the machine control
Error in the drive control
Drive wheel becomes
sluggish due to foreign
particles
Drive motor overheats
Seat permanently loaded
Cables on the battery
poles loose or detached
Incorrect type of battery
installed
Connected consumer
overloaded
Internal controller defect
Operation
Remedy
Inspect the side
brushes for foreign
particles and remove
them if necessary
Inspect for foreign
particles and remove
them if necessary
Notify service partner
Notify service partner
See maintenance
plan
Machine OFF/ON
Machine OFF/ON, or
notify service partner
if necessary
Remove foreign
particles
Let the engine cool
down
Relieve seat
Notify service partner
Contact the
customer service
Install correct battery
Check whether the
consumer is drawing
too much power or
there is a short-circuit
in the connected
cable.
Notify service partner
61