Maintenance and Servicing
Filling the solution tank with the fast fill station
The filling opening of the solution tank can be increased when filling with the
fast fill station by unscrewing the grey cover Fig. 31-A and removing it
Fig. 31-B.
Fig. 31:
Filling the solution tank with the automatic filling unit
Optionally, the solution tank can be filled via the automatic filling unit.
B
Fig. 32:
1. Fit the hose with the quick coupler Fig. 32-A. Do not yet open the water
supply!
2. Push the operating button Fig. 32-B. The indicator knob Fig. 32-C
protrudes.
3. Open the water supply – water starts to flow.
4. The filling unit switches off automatically when the tank is full. The indicator
knob Fig. 32-C no longer protrudes.
5. Close the water supply and remove the hose with the quick coupling.
Use a water line fitted with a stop valve!
Note
The machine can also be filled manually through the opening in the
operating button Fig. 32-B.
76
A
max. 50 °C
min. 2.5 bar
max. 6 bar
A
C
B
05-7182-01.fm