Maintenance and Servicing
Charging the battery with a stationary charger
Charge the batteries with a stationary charger as, for example, shown in
Fig. 25-A. The batteries can be charged if the battery capacity is less
than 60 %.
Note
For safe charging, the Hako charger and the battery have a safety
circuit (pilot contact control unit).
The charger (99400110) can only charge batteries that have the
PCCU circuit Fig. 25-B.
E
Fig. 25:
1. Place the machine on a level surface and turn it off.
2. Open the seat console and leave it open during loading!
3. Remove the battery plug Fig. 25-C from the plug of the machine Fig. 25-D.
4. Connect the battery plug to the plug of the charger Fig. 25-E and position it
in front of the battery trough Fig. 25-F.
5. Switch on the charger.
6. The progress of the charging process is displayed in the display Fig. 25-G
of the charger.
7. Once the battery is fully charged, terminate the charging process:
• Turn off the charger and wait approx. 15 minutes with the seat console
open.
• Disconnect the battery plug from the plug of the charger and reconnect it
to the plug of the machine Fig. 25-D.