Fig. 47:
Daily cleaning in the event of light soiling
External water connection:
1. Sit on the seat of the machine and switch on the machine.
2. In the sub-menu, call up menu item Maintenance page Fig. 47-A. Select
soft key Squeegee cleaning Fig. 47-B with the turn-push knob and activate.
The squeegee is lowered and the suction is switched on. The remaining
squeegee cleaning time is displayed in 5 second intervals.
3. Move the machine forward a little so that the sealing lips are tilted back.
4. Connect hose to the connection of the squeegee Fig. 47-C using the
1/2" quick coupling, and to the water tap of the service connection.
5. Open the water tap all the way.
Squeegee is cleaned by the internal spray nozzles.
6. After the program has ended, close the water tap and remove the hose.
On-board water connection:
Follow point 1-3 of section External water connection.
4. Disconnect hose from the spray nozzle Fig. 47-D and attach to the squee-
gee connection Fig. 47-C.
5. The squeegee is cleaned by the internal nozzles.
6. After the program has ended, remove the hose from the squeegee during
the after-run time of the suction turbine and reconnect to the spray nozzle.
Attention
If the hose is not disconnected from the squeegee after the program
has ended, the water may run out of the solution tank!