Control Menu; Tab; Message Recognizer - Lightware UMX-TPS-TX100 Series User Manual

Hide thumbs Also See for UMX-TPS-TX100 Series:
Table of Contents

Advertisement

 
5. Software Control - Lightware Device Controller
5.8. Control Menu
5.8.1. RS-232 Tab
The following settings and functions are available on the local and TPS link RS-232 port:
RS-232 mode: Control, Pass-through, and Command Injection (for more details about serial interface
modes see the
Technical Background
Baud rate: 4800, 7200, 9600, 14400, 19200, 38400, 57600, 115200;
Data bits: 8 or 9;
Parity: None, Odd, or Even;
Stop bits: 1, 1.5, or 2;
Command injection: enable or disable;
Command injection port number;
Control protocol: LW2 or LW3;
Message sending via serial port;
Reloading factory defaults (see factory default settings in the
ATTENTION! The RS-232 Operation mode is mirrored on the Local and TPS out serial port. The other settings
can be adjusted separately on the two ports.
RS-232 tab in Control menu
section);
Factory Default Settings
UMX-TPS-TX100 series – User's Manual
5.8.2. Message Recognizer
INFO: This feature is available only in UMX-TPS-TX140-Plus and WP-UMX-TPS-TX130-US models.
UMX-TPS-TX140-Plus model can analyze and store
the received serial data. For more information see the
RS-232 Recognizer
Put a tick to Enable message recognizer on this port to switch
the recognizer on.
Delimiter sequence text box is for set the delimiter string in
hex format. When this string is detected in the incoming
serial data, the device saves the RS-232 message data
from the first bit, until the delimiter (or the data between
the two delimiters).
INFO: 0D0A is the factory default value, this is the
hexadecimal code of Carriage Return and Line Feed.
LW3 protocol commands ended with this formula, so
the default value support the recognition of the LW3
commands and the stored changes automatically.
If the Timeout is enabled and set, the received data is
saved when the timeout is elapsed after the last received
message.
In Received messages box shows the last received
and stored message in Text (RECOGNIZER.Rx), Hex
(RECOGNIZER.RxHex), and Hash (RECOGNIZER.Hash)
format. The Hex and Hash contains the delimiter.
Press the Clear button to erase this storage.
Clicking on Reload restores the
of the recognizer.
ATTENTION! The Message recognizer settings are mirrored on the Local and TPS out serial port.
INFO: Message recognizer operates independently of the RS-232 mode.
section).
section.
Factory Default Settings
52