Release Notes Of The Firmware Packages - Lightware UMX-TPS-TX100 Series User Manual

Hide thumbs Also See for UMX-TPS-TX100 Series:
Table of Contents

Advertisement

 
11. Appendix
11.9. Release Notes of the Firmware Packages
v1.4.0b8
Release date: 2019-07-23
New feature:
▪ Added support for FP-UMX-TPS-TX120-GES, FP-UMX-TPS-
TX130-GES product variants.
▪ New bootloader is used, which allows the connected TPS-RX95's
to be upgraded remotely.
▪ Crosspoint properties and methods changed. Warning: If you
are using an external controller for this device via LW3 protocol,
the recent changes in property and node names may result in
difficulties to control the TPS device with the latest firmware.
▪ WP-UMX-TPS-TX100-WHITE products are now supported.
▪ The method of storing device settings in EEPROM is upgraded,
which may result in losing all the settings, logs and user EDID's
after upgrading to 1.1.0. The LDU software contains a plug-in to
help you keep the actual settings after firmware upgrade.
▪ Event Manager configuration became more user friendly: actions
can be triggered manually for testing and the user interface
shows if any of the conditions are met.
▪ Event Manager upgraded: time delay can be configured between
condition and action, a condition can trigger multiple actions at
the same time, inverse condition can be used.
▪ 3840x2160p60 YUV4:2:0 factory EDID added.
▪ IR command injection is now supported: data received on a
specific TCP port is transmitted as IR signal, and the received IR
frames are also sent to this TCP connection.
▪ Fan can be controlled manually with setFan() LW3 method.
▪ EDID
node
properties
changed:
MonitorName and AudioInfo properties are added
▪ The device is able to identify IR commands on either the local
or link IR input port. This feature can be connected to Event
Manager, which means, that the device can be programmed to
do various actions, if a specific IR command is detected.
▪ TCP and UDP messages can be sent by the device to control
projectors and any other devices. This feature can also be used
with Event Manager.
▪ Audio and video port names are changed: 'I' is used for inputs
and 'O' is used for outputs, instead of 'P'.
▪ New EDID driver is used, the content of some factory EDID's are
changed according to EDID 1.3 and 1.4 standard.
▪ Autoselection connect and disconnect delay can be configured
via LW3 methods.
▪ Firmware platform library updated
▪ Sending IR codes (SendProntoHex e.g. send max. 200 Byte IR
code with Event Actions) for UMX-TPS-TX140-Plus only!
▪ Added 'Disable default button function' option to support button
customization in Event Manager
▪ Modified RS-232 modes to support SendMessage in Control
mode
▪ CEC - sendCEC command (e.g. turn on the TV with Event Actions)
for WP-UMX-TPS-TX130-Plus only!
▪ LWROS integration compatible for LDU2 only!
▪ Added 'Dark mode' function to turn off front panel LEDs
▪ Modified DP input driver to fix HDCP issue with MacBooks
▪ RS232 Minimal Recognizer for Cisco compatibility (Cisco Login)
for WP-UMX-TPS-TX130-Plus only!
▪ Improved GPIO detection
▪ Use LDU2 v1.2.5 or later for the upgrade!
▪ Added 'User replaceable miniweb slot' to support built-in control
webpage
▪ Added 'Forced button lock' function to lock buttons via protocol
command
Bugfix:
▪ Poe enable state is now reloaded after reboot.
▪ Input video parameter measurement speed improved.
▪ Unsupported dual link DVI EDIDs removed from factory EDID list.
▪ /SYS/MB/UMXDP node renamed to /SYS/MB/DP
PreferredResolution,
▪ Event manager conditions did not work if DP input properties
were selected.
▪ If the user switched to the currently selected port, the output was
disconnected and connected again unnecessarily, which resulted
in a picture drop. Fixed.
▪ Compatibility issues with Gefen HDMI 1.3 HdBaseT extender
fixed.
▪ In case of sending DVI signal on the output, the audio output port
does not indicate signal present.
▪ If the output was set to HDCP Always mode, the signal was
sent out unencrypted, if the input port was disconnected and
connected again. This issue only happened, if the input signal
was also unencrypted.
UMX-TPS-TX100 series – User's Manual
▪ If no sync screen is active, the output resolution is now reported
correctly by the output port.
▪ Reporting the resolution of signals in YUV 4:2:0 colorspace fixed.
▪ In case of sending 1920x1200 no sync screen, the device did not
notice the connection state changes on the inputs. Fixed.
v1.3.2b1
Release date: 2019-05-21
Bugfix:
▪ Use LDU2 v1.2.5 or later for the upgrade!
v1.3.1b1
Release date: 2019-04-17
Bugfix:
▪ bugfix to support for previous HW versions
v1.3.0b11
Release date: 2019-04-17
New feature:
▪ RS232 Minimal Recognizer for Cisco compatibility (Cisco Login)
for UMX-TPS-TX140-Plus only!
▪ Sending IR codes (SendProntoHex e.g. send max. 200 Byte IR
code with Event Actions) for UMX-TPS-TX140-Plus only!
▪ Use LDU2 v1.2.3 or later for the upgrade!
▪ CEC - sendCEC command (e.g. turn on the TV with Event Actions)
for UMX-TPS-TX140-Plus only!
Bugfix:
▪ Fixed Event Manager condition linking
v1.2.1b8
Release date: 2019-01-29
New feature:
▪ Firmware platform library updated
▪ Modified DP input driver to fix HDCP issue with MacBooks
▪ Compatible for LDU2 only!
▪ Modified RS-232 modes to support SendMessage in Control
mode
▪ Added 'Disable default button function' option to support button
customization in Event Manager
122

Advertisement

Table of Contents
loading

Table of Contents