11. Appendix
▪ Added 'Forced button lock' function to lock buttons via protocol
command
▪ Added 'Dark mode' function to turn off front panel LEDs
▪ Video crosspoint driver improvements
▪ AV input driver improvements
▪ Improved GPIO detection speed (quick impulses can be detected,
even low as 80ms)
v1.1.7b2
Release date: 2018-05-18
Bugfix:
▪ Rs232 even parity parameter bug fixed.
v1.1.6b1
Release date: 2018-04-10
New feature:
▪ New control.html.
v1.1.5b1
Release date: 2018-03-01
New feature:
▪ New miniweb.
v1.1.3b1
Release date: 2017-10-18
Bugfix:
▪ Fixed GPIO PortUiCode.
v1.1.2b4
Release date: 2017-10-16
New feature:
▪ The text names of the ports are changed to be more precise, and
less ambiguous.
▪ With too many devices connected, one can find it hard to pair
the physically connected devices with the listed devices in LDC
device discovery window. That is why Lightware is introducing
the new IdentifyMe feature, which identifies the desired device by
blinking its LEDs for a period of time. That helps the user visually
recognize the requested device.
▪ Now Bonjour shows firmware version as well.
UMX-TPS-TX100 series – User's Manual
Bugfix:
▪ Fixed a bug that made the 'continuously exists' timing mode
unable to use.
▪ Fixed a bug that caused Event Manager's 47th event to be unlink-
able.
v1.1.1b1
Release date: 2016-05-11
New feature:
▪ Autoselection connect and disconnect delay can be configured
via LW3 methods.
Bugfix:
▪ Unsupported dual link DVI EDIDs removed from factory EDID list.
▪ Event manager conditions did not work if DP input properties
were selected.
▪ Input background measurement speed improved.
▪ If the user switched to the currently selected port, the output was
disconnected and connected again unnecessarily, which resulted
in a picture drop. Fixed.
▪ /SYS/MB/UMXDP node renamed to /SYS/MB/DP
v1.1.0b1
Release date: 2016-04-11
New feature:
▪ New EDID driver is used, the content of some factory EDID's are
changed according to EDID 1.3 and 1.4 standard.
▪ EDID
node
properties
changed:
PreferredResolution,
MonitorName and AudioInfo properties are added
▪ Audio and video port names are changed: 'I' is used for inputs
and 'O' is used for outputs, instead of 'P'.
▪ Crosspoint properties and methods changed. Warning: If you
are using an external controller for this device via LW3 protocol,
the recent changes in property and node names may result in
difficulties to control the TPS device with the latest firmware.
▪ TCP and UDP messages can be sent by the device to control
projectors and any other devices. This feature can also be used
with Event Manager.
▪ IR command injection is now supported: data received on a
specific TCP port is transmitted as IR signal, and the received IR
frames are also sent to this TCP connection.
▪ The device is able to identify IR commands on either the local
or link IR input port. This feature can be connected to Event
Manager, which means, that the device can be programmed to
do various actions, if a specific IR command is detected.
▪ Factory default can be given in the board component.
▪ New bootloader is used, which allows the connected TPS-RX95's
to be upgraded remotely.
▪ Event Manager upgraded: time delay can be configured between
condition and action, a condition can trigger multiple actions at
the same time, inverse condition can be used.
▪ Dynamic edid can be deleted from code.
▪ 3840x2160p60 YUV4:2:0 factory EDID added.
▪ Event Manager configuration became more user friendly: actions
can be triggered manually for testing and the user interface
shows if any of the conditions are met.
▪ FRAMEWORK update.BUGFIX: Minor bug fix in default emulated
edids.
▪ The method of storing device settings in EEPROM is upgraded,
which may result in losing all the settings, logs and user EDID's
after upgrading to 1.1.0. The LDU software contains a plug-in to
help you keep the actual settings after firmware upgrade.
▪ Default emulated edid for UmxAvFrontend handling changed.
Bugfix:
▪ Error log is accessible at /MANAGEMENT/LOG/RAMLOG node.
▪ If no sync screen is active, the output resolution is now reported
correctly by the output port.
▪ Compatibility issues with Gefen HDMI 1.3 HdBaseT extender
fixed.
▪ Reporting the resolution of signals in YUV 4:2:0 colorspace fixed.
▪ In case of sending DVI signal on the output, the audio output port
does not indicate signal present.
▪ In case of sending 1920x1200 no sync screen, the device did not
notice the connection state changes on the inputs. Fixed.
▪ If the output was set to HDCP Always mode, the signal was
sent out unencrypted, if the input port was disconnected and
connected again. This issue only happened, if the input signal
was also unencrypted.
▪ Poe enable wasn't saved.
▪ Cable diagnostics properties are moved to SYS/MB/TPS/
REMOTE node.