Change The Gateway Address (Static); Port Configuration; Protocol Setting; Baud Rate Setting - Lightware UMX-TPS-TX100 Series User Manual

Hide thumbs Also See for UMX-TPS-TX100 Series:
Table of Contents

Advertisement

 
7. LW3 Programmers' Reference
7.7.8. Change the Gateway Address (Static)
Command and Response
SET·/MANAGEMENT/NETWORK.StaticGatewayAddress=<gw_address>
Î
pw·/MANAGEMENT/NETWORK.StaticGatewayAddress=<gw_address>
Í
Example
Î SET /MANAGEMENT/NETWORK.StaticGatewayAddress=192.168.0.5
Í pw /MANAGEMENT/NETWORK.StaticGatewayAddress=192.168.0.5
7.8. RS-232 Port Configuration
INFO: Serial port numbering can be found in the
7.8.1. Protocol Setting
Command and Response
SET·/MEDIA/UART/<port>.ControlProtocol=<protocol>
Î
pw·/MEDIA/UART/<port>.ControlProtocol=<protocol>
Í
Parameters
Identifier
Parameter description
Control protocol which is
<protocol>
applied on the selected
serial port
Example
Î SET /MEDIA/UART/P1.ControlProtocol=1
Í pw /MEDIA/UART/P1.ControlProtocol=1
Port Numbering
section.
Value
Parameter value
0
LW2 protocol
1
LW3 protocol
UMX-TPS-TX100 series – User's Manual
7.8.2. BAUD Rate Setting
Command and Response
SET·/MEDIA/UART/<port>.Baudrate=<baudrate>
Î
pw·/MEDIA/UART/<port>.Baudrate=<baudrate>
Í
Parameters
Identifier
Parameter description
<baudrate>
Example
Î SET /MEDIA/UART/P1.Baudrate=2
Í pw /MEDIA/UART/P1.Baudrate=2
7.8.3. Databits Setting
Command and Response
SET·/MEDIA/UART/<port>.DataBits=<databits>
Î
pw·/MEDIA/UART/<port>.DataBits=<databits>
Í
Parameters
Identifier
Parameter description
<databits>
Example
Î SET /MEDIA/UART/P1.DataBits=8
Í pw /MEDIA/UART/P1.DataBits=8
Value
0
4800
1
7200
2
9600
3
14400
BAUD rate value
4
19200
5
38400
6
57600
7
115200
Value
8
8
Databits value
9
9
88
Parameter value
Parameter value