o2-04 Drive / kVA Selection
Setting Range:
0 to FF
Factory Default: Model Dependent
Parameter o2-04 matches the control board to the iQpump drive hardware. Proper setting of o2-04 is important so that the control board
can provide proper protection for the iQpump drive hardware. This parameter is configured at the factory and does not normally require
adjustment in the field. It is available primarily to accommodate control board replacement in the event of damage.
208-230/240 Vac
Model Number
20P4
20P7
21P5
22P2
23P7
27P5
2011
2015
2018
2022
2030
2037
2045
2055
2075
2090
2110
The factory defaults of the following parameters may be changed when the setting of o2-04 is changed:
• b8-04 (Energy Saving Coefficient Value)
• C6-02 (Carrier Frequency Selection)
• E2-01 (Motor Rated Current)
• E2-03 (Motor No-Load Current)
• E2-05 (Motor Line-to-Line Resistance)
• L2-02 (MPL Ride-Thru Time)
• L2-03 (MPL Minimum Base Block Time)
• L2-04 (MPL Voltage Recovery Ramp Time)
• L8-02 (Overheat Pre-Alarm Level)
• L8-06 (Input Phase Loss Detection Level)
YASKAWA TM.iQp.02 iQpump Drive Programming Manual
Table 29 kVA Settings by iQpump Drive Model Number
Proper
o2-04 Setting
0
1
2
3
4
6
7
8
9
A
B
C
D
E
F
10
11
480 Vac
Model Number
40P4
40P7
41P5
42P2
43P7
45P5
47P5
49P0
4011
4015
4018
4022
4024
4030
4037
4045
4055
4075
4090
4110
4160
4185
4220
4300
Proper
o2-04 Setting
20
21
22
23
24
26
27
3C
28
29
2A
2B
3D
2C
2D
2E
2F
30
31
32
34
35
36
37